Dual Application Master Flow Canvas

Interactive System Architecture & End-to-End Visual Workflow

Shared Property Core
24/7 Monitoring (ACMS)
Audit & Compliance (SaaS)
Microservices Mesh
Architectural Master Canvas • Non-Technical & Executive Blueprint

One Common Core. Two Specialized Powerhouses.

Welcome to the master blueprint of the Forteza Enterprise Platform. This visual canvas illustrates how the 24/7 Central Alarm Monitoring System (replacing the legacy MicroKey desktop app) and the Commercial SaaS Audit Platform (replacing the old PHP inspection tool) coexist seamlessly around a single, unified Property Master Registry.

💡
Non-Technical Client Takeaway: You never type a building address, emergency phone number, or floor layout twice! Once a property is registered in the Golden Bridge (top), your internal 24/7 team can immediately monitor it for fire/burglary emergencies, and your external paying clients can inspect it for safety compliance.
🏛️

THE GOLDEN BRIDGE: Central Property Master Service

Single Source of Truth • Registered Once • Shared Automatically Across Both Applications

● Live Master Sync
🏢 Premise & Building Profile

Physical address, municipal registration number, plot survey, building height, floor count, and building occupancy type.

building_id name address height_val occupancy
📍 Geographic & Estate GIS

Exact GPS coordinates, campus parent complex, access gates, approach road widths, and nearest cross-street landmarks.

latitude longitude complex_id cross_streets
👥 Keyholder Roster

Building managers, security chiefs, and technicians ranked in strict call-priority sequence with verbal passwords.

contact_name phone_primary priority_order verbal_password
🚓 Municipal PSAP Jurisdiction

Direct dispatch phone numbers for local police departments, fire brigade stations, and emergency medical PSAPs.

town_code fire_dispatch_phone police_phone permit_req
📌
Architecture Note: Property records are stored in high-performance PostgreSQL with strict ACID transactions. Both the Monitoring Service and Audit Service query this central service through fast internal microservice gRPC / REST calls.
Propagates to Monitoring Engine (ACMS)
Propagates to Commercial SaaS Audit Engine
🚨

1. Forteza 24/7 Monitoring System (ACMS)

Sub-Second Alarm Processing & Central Station Automation

Internal Forteza Dispatch Team Only • Private Platform
1 Physical Sensor Trigger at Premise
Field Hardware

A physical optical smoke detector on the 3rd floor detects smoke particles. The local fire panel triggers loop terminal #001 and transmits via AES radio frequency to the central tower.

📊 Active Data Properties at Step 1
device_type Optical Smoke Detector
loop_zone 001 (Hardwired input)
panel_account 1001 (Hex CSID)
⚠️
Critical: At this stage, raw field hardware only knows numerical account 1001 and zone 001. It has zero concept of customer names or street addresses!
▼
2 TCP Ingestion & Instant Protocol ACK
Monitoring Service (TCP Socket)

The Forteza persistent TCP socket listener catches the raw byte frame from AES-IntelliNet INCC receiver. To prevent receiver communication timeouts, Forteza immediately emits the required protocol ACK buffer.

📊 Active Data Properties at Step 2
raw_stream \n11 1001 18 E110 00 C001 \r
auto_ack_sent \n00 OKAY @\r
ingestion_latency < 15 ms
⚡
Zero Loss Guarantee: The raw frame is flushed to disk storage BEFORE parsing starts. Even if the server loses power, no alarm packet is ever lost.
▼
3 Ademco 685 Frame Parsing & Normalization
Protocol Normalizer

The raw Ademco frame is tokenized into standard Contact ID fields: Receiver/Line, Account, Event Qualifier ('E' = Active Alarm), Alarm Code (110 = Fire Alarm), and Zone ID (001).

📊 Active Data Properties at Step 3
event_qualifier 'E' (New Active Alarm)
event_code 110 (Fire Alarm)
priority_grade Priority 1 (Life Safety)
▼
4 Property Master Crosswalk Resolution
Golden Bridge Link

The Crosswalk queries the Golden Bridge Property Service to match Account 1001 to a real building, and Zone 001 to the exact physical room.

📊 Active Data Properties at Step 4 (Enriched)
resolved_building Shirke Mhada Bldg No. 5
resolved_location 3rd Floor, Server Room
soak_test_status LIVE (Not in Test Mode)
assigned_action_plan VERIFY_FIRST_THEN_DISPATCH
✨
Magic Moment: Cryptic telemetry numbers are transformed into human actionable intelligence in less than 30 milliseconds!
▼
5 WebSocket Broadcast to Live CAD Alarm Board
React CAD Console (Operator UI)

The enriched incident is pushed via WebSockets to all logged-in central station dispatchers. The browser screen flashes red and triggers an audible emergency siren tone.

📊 Active Data Properties at Step 5
incident_id inc_9847192
board_queue_rank #1 (Top of Queue)
operator_claim_lock UNLOCKED (Flashing)
🔒
Operator Locking: When Dispatcher "Sarah" clicks [CLAIM INCIDENT], the incident locks immediately. Other operators see "Handled by Sarah", eliminating double calls and confusion!
▼
6 Interactive Action Plan & Phone Verification
Dispatcher SOP Guidance

The operator console loads the step-by-step SOP. The dispatcher clicks to auto-dial the building security desk. They ask the security guard for the secret verbal password to verify if it is a false alarm or a real fire.

📊 Active Data Properties at Step 6
premise_contact +91 98200 12345 (Security)
secret_verbal_pwd "FALCON"
disposition_buttons [REAL FIRE] | [FALSE] | [NO ANSWER]
▼
7 Municipal Fire PSAP Dispatch & SMS Broadcast
Emergency Dispatch Gateway

If a real fire is confirmed or premise does not answer, the console displays the exact local Fire Station direct telephone line with a pre-scripted readout. Simultaneously, automated SMS alerts broadcast to all property keyholders.

📊 Active Data Properties at Step 7
psap_fire_phone 022-24072222 (Dharavi Station)
pre_scripted_readout "Fire confirmed Bldg 5, 3rd Fl..."
sms_recipients 3 Keyholders Dispatched
▼
8 Incident Closure & Forensic Legal Audit Trail
Forensic Compliance Log

The dispatcher selects final resolution code (VALID_FIRE_DISPATCH), enters closing notes, and concludes the ticket. Every ring, millisecond, and operator decision is recorded permanently for legal and insurance defense.

📊 Active Data Properties at Step 8
resolution_code VALID_FIRE_DISPATCH
handling_duration 1m 42s (Complies with UL 827)
cryptographic_hash SHA256: 8f92a17... (Immutable)
📋

2. Forteza Audit & Compliance Platform (SaaS)

Commercial Inspection Platform & Defect Management Suite

Commercial Multi-Tenant SaaS • External Subscribers
1 Customer Self-Signup & SaaS Plan Selection
Commercial Tenant Portal

A facility management company or building owner signs up on the Forteza SaaS portal. They select a monthly subscription plan (e.g. "Commercial Pro: Up to 10 Buildings") and enter payment info via Stripe.

📊 Active Data Properties at Step 1
subscriber_org Shirke Property Managers Ltd
plan_tier Commercial Pro ($199/mo)
licensed_quota 10 Buildings, 5 Auditor Seats
💰
Recurring Revenue: This transforms Forteza from an internal cost center into a commercial recurring SaaS software revenue business!
▼
2 Building Onboarding into Shared Property Core
Golden Bridge Link

The customer uses the registration wizard in the React frontend to add their building profile (height, 14 floors, residential occupancy, lift shafts, staircase widths).

📊 Active Data Properties at Step 2 (Shared Core)
building_name Shirke Mhada Bldg No. 5
municipal_reg_no MH-CFO-DHA-501
height_and_floors 45 Meters / 14 Floors
staircase_count 2 Fire-Resistant Staircases
🔗
Dual-Use Asset: This building record is saved into the same shared database that the 24/7 Monitoring System uses!
▼
3 Physical Safety Equipment Asset Tagging
Asset Registry Module

The client or technician catalogs individual safety assets throughout the building: fire pump rooms, hydrant valves, wet risers, sprinkler heads, and portable ABC extinguishers with QR barcodes.

📊 Active Data Properties at Step 3
asset_tag_id EXT_FL3_04 (QR Barcode)
asset_category CO2 4.5kg Fire Extinguisher
expiry_refill_date 2027-04-15
location_tag Floor 3 Near Server Room
▼
4 Audit Template Selection & Scheduling
Audit Planning Module

The safety director selects a certified compliance template (e.g. "Annual High-Rise Fire Audit - NBC Part IV") and schedules an inspection, assigning a licensed fire auditor.

📊 Active Data Properties at Step 4
template_code TPL_NBC_HIGHRISE_V2
passing_threshold 80% Minimum Score
assigned_auditor Ar. Sameer Desai (Lic #441)
scheduled_date 2026-11-15
▼
5 Field Audit Execution via Mobile / Tablet
Field Inspector Workspace

The inspector arrives on-site and opens the mobile-optimized checklist. They inspect pump pressure gauges, illuminated exit signs, panic hardware, and verify equipment QR codes.

📊 Active Data Properties at Step 5
checklist_section Staircase & Egress Lighting
item_1_result PASS (Battery Backup OK)
item_2_result FAIL (Exit Obstruction)
offline_mode Supported (Local IndexedDB)
▼
6 Defect Logging with Geotagged Photo Proof
Deficiency & Evidence Log

For any failed checklist item, the auditor uses their camera to snap a photo, draws a highlight circle over the issue, logs GPS coordinates, and assigns a defect severity level.

📊 Active Data Properties at Step 6
defect_title Staircase A Door Blocked
defect_severity CRITICAL (Life Safety Violation)
evidence_photo s3://forteza/bld5/staircase.jpg
resolution_deadline Within 24 Hours
▼
7 Corrective Action Workflow (CAPA)
Facility Maintenance Contractor

The building manager gets an instant notification. They assign the work order to their facilities team. The contractor removes the obstruction, uploads a "Rectification Photo", and requests sign-off.

📊 Active Data Properties at Step 7
capa_ticket_id CAPA-2026-081
rectification_photo s3://forteza/bld5/cleared.jpg
reinspection_status VERIFIED & APPROVED
▼
8 Scoring & PDF Compliance Certificate
Certification Engine

With all deficiencies cleared, the engine calculates the final score (96%). Digital signatures from the auditor and building chairman are stamped onto an official PDF Certificate with a public QR verification seal.

📊 Active Data Properties at Step 8
composite_score 96.5% (GRADE: EXCELLENT)
certificate_no CERT-MH-2026-5591
validity_period 1 Year (Expires Nov 2027)
qr_verification_url https://verify.forteza.com/c/5591