🏒 24/7 Life Safety & SaaS Compliance Platform

Forteza Unified Enterprise Ecosystem

Comprehensive Architectural Specification, Module Distribution, End-to-End Data Flow, and Implementation Blueprint for Migrating Legacy MicroKey Desktop & PHP Auditing to a Scalable Cloud Microservices Platform.

Primary Systems 1. Monitoring CAD  |  2. SaaS Audit
Core Philosophy Property-First Unified Master Registry
Hardware Protocol AES-IntelliNet INCC (Ademco 685 / Contact ID)
Frontend & Access Single React Web App with Strict RBAC
1

The Strategic Vision: Dual-System Enterprise

Modernizing Two Separate Workflows into One Harmonious Engine

The client’s business currently operates with two distinct requirements that were historically siloed. The objective of this transformation is to elevate both workflows into an interconnected, modern, cloud-native technology stack sharing a single source of property truth.

πŸ’‘
Non-Technical Explanation: What Are We Building?
Think of Forteza as an airport:
β€’ The Monitoring System is like the Air Traffic Control Tower: It runs 24/7/365, used exclusively by your internal expert team. When an emergency happens (e.g. fire, intrusion, power loss), alarm signals scream into the system in milliseconds. Your dispatchers immediately see who is in danger, which exact room triggered the alarm, and are guided step-by-step to alert the police, fire department, and property owners.
β€’ The Audit System is like the Aircraft Safety Inspector: It is sold to external customers as a subscription (SaaS). Property owners, safety consultants, and facility managers log in to inspect fire extinguishers, sprinklers, exits, and electrical systems. It gives them digital checklists, photos of defects, compliance scores, and official safety certificates.
β€’ The Shared Property Registry is the Official Passport & Building Database: Neither system has to type the building address, floors, or emergency contacts twice. Both systems look at the exact same building profile!
System A β€’ Internal & Dedicated

Forteza 24/7 Monitoring (ACMS)

Central Station Automation (Replacing MicroKey Desktop)

🎯
Target Users: Client’s internal central station operators, dispatchers, and supervisors only. Not open to the public.
πŸ“‘
Data Source: Real-time hardware telemetry from AES-IntelliNet INCC via TCP socket using Ademco 685 / Contact ID protocol.
⚑
Speed Requirement: Sub-second (Real-time WebSockets, zero delay, audible audio alerts, high-pressure CAD screen).
πŸ“‹
Key Purpose: Emergency signal decoding, immediate operator claiming, scripted action plan execution, 911/PSAP dispatch, and legal incident CAD logs.
πŸ”„
Legacy Status: Replaces obsolete, complex Windows desktop software (MicroKey / Millennium CSID).
System B β€’ Commercial SaaS

Forteza Audit & Compliance Platform

Multi-Tenant Inspection SaaS (Replacing Legacy PHP Script)

πŸ‘₯
Target Users: Commercial external subscribers, facility management agencies, building owners, third-party fire auditors.
πŸ’³
Business Model: Multi-tenant SaaS subscription plans (Monthly/Annual billing, per-building or per-auditor limits).
πŸ”
Key Purpose: Fire safety audits, NFPA/NBC/CFO regulatory checklists, asset tagging (pumps, hydrants, extinguishers), photo evidence, and deficiency tracking.
πŸ“œ
Deliverables: Digital inspection reports, automated compliance scoring (Pass/Fail/Conditional), and official safety certificates.
πŸ”„
Legacy Status: Replaces simple legacy single-file PHP website with a high-class, scalable enterprise app.
⚠️
Important Rule: Data Privacy & Isolation
Because the Monitoring System contains confidential internal emergency response protocols, police dispatch credentials, and live alarm telemetry, external SaaS audit customers can NEVER see or access the live monitoring queue. The Single React Application will strictly enforce role boundaries: a SaaS customer only sees their subscribed buildings and audit tools, while the Forteza internal team has a dedicated Central Monitoring Console.
2

The Core Philosophy: "Property-First" Master Data

Building Details Registered ONCE, Shared Seamlessly Across Both Systems

Your foundational architectural insight is 100% accurate and industry best-practice: Both systems revolve around the exact same physical assetβ€”the Building/Property. Instead of having separate building databases for Monitoring and Audit, we establish a Central Property Master Service.

πŸ›οΈ

1. Common Shared Property Data

Registered once during onboarding. Shared by both Monitoring and Audit:

  • β€’ Organization & Subscriber Info: Legal entity, billing info, account owner.
  • β€’ Campus / Complex: Parent campus (e.g., "Phoenix Tech Park").
  • β€’ Building Profile: Name, Municipal Reg #, Plot & Survey #, Height, Number of Floors.
  • β€’ Geographic Coordinates: Exact GPS Latitude & Longitude, Map view, approach roads.
  • β€’ Structural Elements: Wings, staircases, fire lifts, basement levels.
  • β€’ Keyholder Contacts: Building manager, security head, technician names & phone numbers.
  • β€’ Municipal Town Codes: Jurisdiction police station, fire station phone numbers, emergency PSAP.

🚨 Monitoring System Config (Attached to Property)

  • β€’ Panel CSID / Account: 4-digit Hex ID (e.g., 1001) matching INCC.
  • β€’ Zone Mappings: Zone 001 = "3rd Floor Server Room Smoke Detector".
  • β€’ Action Plans: SOP rule (e.g. "Auto-call keyholder #1; if no answer, dial 911").
  • β€’ Verbal Passwords & Duress: Secret words to verify authorized personnel over phone.
  • β€’ Soak Test Schedule: Suppress dispatch while technicians test panels.

πŸ“‹ Audit System Config (Attached to Property)

  • β€’ Equipment Registry: Pumps, sprinkler heads, extinguishers (with barcodes & expiry).
  • β€’ Audit Templates: NFPA 101, National Building Code, CFO checklist questions.
  • β€’ Inspection Plans: Scheduled frequency (Quarterly, Semi-Annual, Annual).
  • β€’ Assigned Auditors: Licensed fire safety officers assigned to inspect this site.
  • β€’ Compliance History: Past scores, open deficiencies, issued certificates.
πŸ“Œ
Strategic Business Advantage of This Approach
If a customer starts out simply buying the SaaS Audit System to inspect their building, they have already added all their building details, floors, and emergency contacts. If they later decide to hire your team for 24/7 Live Monitoring, you can activate monitoring with zero duplicate data entry! You simply attach an INCC panel CSID account number to their existing building.
3

Backend Microservices Architecture

Modern, Scalable, Fault-Tolerant Distributed Services

To ensure high scalability, independent deployments, and airtight security, the backend is partitioned into specialized microservices communicating over high-speed REST APIs, Redis message brokers, and persistent TCP sockets.

Layer 1: Unified Frontend & External Gateways
πŸ’»
React Web App
Single responsive frontend with role-gated views (Dispatcher vs SaaS Auditor)
πŸ“±
Auditor Field App
Mobile/Tablet optimized inspection & photo upload interface
πŸ“‘
AES-IntelliNet INCC
Physical/Virtual alarm receiver emitting Ademco 685 streams over TCP
β–Ό   Secured TLS / WebSocket / TCP Connections   β–Ό
Layer 2: API Gateway & Traffic Routing
Enterprise API Gateway & WebSocket Router
Central authentication validation, rate limiting, SSL termination, and real-time WebSocket distribution
β–Ό   Internal Microservices Mesh   β–Ό
Layer 3: The 6 Core Microservices
πŸ”
1. Auth Service
JWT tokens, multi-tenant RBAC, login security, permission policies.
πŸ›οΈ
2. Property Service
Master Premise Registry: Buildings, Floors, Zones, Equipment & Contacts.
πŸ’³
3. Subscriber Service
SaaS plans, subscriptions, Stripe billing, customer tenant isolation.
πŸ“²
4. Notification Service
SMS alerts (Twilio), Email (SendGrid), Push notifications & voice TTS.
🚨
5. Monitoring Service
TCP INCC receiver, Ademco 685 parser, live CAD queue & action plans.
πŸ“
6. Audit Service
Templates, schedules, running audits, scoring & certificate generator.
β–Ό   High-Speed Data & Event Store   β–Ό
Layer 4: Polyglot Persistence & Caching
PostgreSQL Database
Relational master records: Properties, Contacts, CSID Panels, Action Plans, SaaS Billing.
MongoDB Database
Flexible audit checklists, dynamic inspection findings, photo references & raw INCC packet logs.
Redis In-Memory Cache
Real-time alarm queue, active operator lock sessions, WebSocket pub/sub channels.
4

Monitoring System (ACMS): Module Breakdown

The 8 Specialized Modules Replacing the MicroKey Desktop Application

The Central Alarm Monitoring System handles mission-critical life safety events. It guarantees zero signal loss, instant cross-referencing, automated SOPs, and full legal compliance. Below are the 8 Core Modules covered in the Monitoring System:

πŸ“‘
Module M1

INCC Ingestion & Protocol Parser

Asynchronous TCP socket listener connecting directly to AES-IntelliNet INCC. Implements automatic heartbeat ACK ( 00 OKAY @ ) and parses Ademco 685 / Contact ID packets.

  • TCP stream buffering & auto-reconnect
  • Ademco 685 frame token extraction
  • Event Qualifier resolution (Alarm 'E' vs Restoral 'R')
  • Raw packet immutable logging to disk
πŸ—ΊοΈ
Module M2

Entity Crosswalk & Mapping Registry

Enriches cryptic hardware numbers into clear human descriptions. Bridges the raw CSID Account ID and Zone number directly into the Property Database.

  • Account CSID β†’ Building & Floor resolver
  • Zone Number β†’ Sensor & Room label resolver
  • Alarm Condition (Fire, Panic, Burglary) mapper
  • Unmapped hardware alert generator
βš™οΈ
Module M3

Signal Deduplication & Storm Filter

Prevents dispatcher panic during alarm floods. When a lightning strike or faulty loop triggers 50 signals a second, this module aggregates and suppresses duplicates.

  • Configurable suppression time windows
  • Multi-knock verification correlation
  • Restoral auto-clearing logic
  • Runaway transmitter cutoff protection
🚨
Module M4

Live 24/7 CAD Alarm Board & Queue

The primary interface for dispatchers. Displays active alarms ranked by priority, flashing colors, audible tones, and instant operator claim locks to prevent duplicate handling.

  • Sub-second WebSocket push notifications
  • Priority sorting (Priority 1 Fire/Panic at top)
  • Single-operator claim lock (prevents double work)
  • Live estate map with flashing incident pins
πŸ“–
Module M5

Action Plans & Operator Guidance

Guides the dispatcher through standard operating procedures (SOPs). Replaces human guesswork under stress with step-by-step decision trees and scripted emergency dialogs.

  • Emergency Call Verification (ECV) workflows
  • Scripted prompts for police and fire dispatch
  • One-click disposition buttons (Passcode OK, Wrong No)
  • Escalation timers if operator takes too long
πŸ“ž
Module M6

People-To-Call Escalation Tree

Manages keyholders and emergency response rosters. Automatically calls phone numbers in strictly configured sequence (Primary, Secondary, Mobile, Pager) until acknowledged.

  • Ranked calling sequence (1st, 2nd, 3rd)
  • Integrated Click-to-Call telephony gateway
  • Verbal password and covert duress verification
  • Automatic SMS/Email notification broadcasts
πŸš“
Module M7

Municipal Town Codes & PSAP Dispatch

Contains specific jurisdictional dispatch phone numbers for local police departments, fire districts, and emergency dispatch centers based on the building’s location.

  • Local Police/Fire direct dispatch telephone lines
  • Permit requirements & false-alarm limits
  • Special cross-street navigation instructions
  • Dispatch cancellation protocol numbers
πŸ›‘οΈ
Module M8

Test Mode & Forensic Audit Trail

Allows technicians to place accounts into 'Soak/Test Mode' during maintenance, preventing false dispatches. Cryptographically logs every action for legal compliance.

  • Time-bound Soak Testing (e.g., Test for 2 hours)
  • Temporary dispatcher notes with active date windows
  • Immutable incident history log with timestamps
  • UL 827 & NFPA compliance reports
5

Audit System: Module Breakdown

The 8 Commercial Modules Replacing the Legacy PHP Audit Script

The Audit System is a commercial SaaS solution. It enables facility managers, building societies, and licensed inspection companies to conduct structured on-site audits, record compliance, track equipment, and produce legal certificates. Below are the 8 Core Modules covered in the Audit System:

πŸ“
Module A1

Audit Checklist & Template Builder

Configures standardized inspection checklists based on regional and international safety codes (e.g. NFPA 10, NFPA 72, National Building Code, Local Fire Brigade standards).

  • Drag-and-drop category & question builder
  • Multi-type answers (Pass/Fail, Numeric, Yes/No/NA)
  • Severity weighting (Critical, Major, Minor)
  • Pre-built library of fire safety templates
🧯
Module A2

Physical Equipment & Asset Registry

Inventories every physical safety asset inside the building. Allows QR code/barcode scanning to verify individual extinguishers, fire pumps, hose reels, and smoke barriers.

  • Asset cataloging (Manufacturer, Model, Serial No)
  • Floor & wing exact location mapping
  • Hydrostatic test & pressure gauge expiry dates
  • Individual equipment maintenance history
πŸ“…
Module A3

Audit Planning & Auditor Scheduling

Schedules recurring inspection campaigns across multiple complexes and buildings. Dispatches qualified inspectors based on location and certification credentials.

  • Automated recurring schedules (Monthly, Annual)
  • Inspector assignment & calendar booking
  • Automated email & calendar invites to building owners
  • Overdue audit notification reminders
πŸ“±
Module A4

Running Audit Execution (Field App)

The digital clipboard used by inspectors while walking the building. Responsive and lightweight for mobile phones and tablets, allowing quick item verification.

  • Step-by-step room and floor checklist view
  • Auto-saving drafts in progress
  • Offline caching for basement inspections
  • One-touch scoring calculation
πŸ“·
Module A5

Photo Evidence & Observation Log

Eliminates disputes by capturing photographic evidence for every failed check. Attaches GPS location and camera timestamps to substantiate non-compliance findings.

  • Direct camera capture & gallery upload
  • Annotate photos (draw circles, arrows on defects)
  • Inspector field notes and audio dictation
  • Secure S3 cloud storage with CDN links
πŸ”§
Module A6

Deficiencies & Corrective Actions (CAPA)

Converts audit failures into actionable work orders. Assigns repair tasks to facility maintenance contractors and tracks re-inspection verification.

  • Deficiency priority grading (Critical / High / Low)
  • Contractor assignment & resolution deadlines
  • Contractor repair proof photo submission
  • Closed-loop re-verification sign-off
πŸ“œ
Module A7

Scoring & Certificate Generator

Calculates the composite compliance score and automatically generates high-resolution, print-ready PDF Fire Safety Certificates with digital signatures and QR verification.

  • Algorithmic score calculation (e.g. 94% Compliant)
  • Pass / Conditional / Fail outcome badge
  • Digital signature pad for auditor and owner
  • Cryptographic QR code for public validation
πŸ’³
Module A8

SaaS Tenant & Subscription Billing

Enables Forteza to monetize the audit platform. External customers sign up, choose a monthly or annual tier, enter credit card details, and manage their organization users.

  • Multi-tenant organization data isolation
  • Tiered plans (Starter 5 buildings vs Enterprise unlimited)
  • Automated Stripe invoice and payment processing
  • Usage metrics, limits & plan upgrades
6

Step-by-Step Flow: Live Alarm Monitoring (ACMS)

From Physical Sensor Trigger to Real-Time Dispatch and Resolution

Here is the exact journey of an emergency alert through the Forteza Monitoring System. Every stage is clearly detailed with the underlying data properties so both non-technical managers and software engineers understand the transformation.

1

Physical Sensor Trigger at Customer Premise

Field Hardware

A smoke detector triggers on the 3rd floor of a commercial building. The on-site fire panel creates an Ademco Contact ID event and transmits it over AES radio frequency to the central tower.

Property / FieldValueMeaning / Purpose
hardware_typeOptical Smoke SensorDevice sensing combustion particles
loop_zone001Physical input terminal wire on panel
panel_csid10014-digit Hex Customer Account Identifier
2

Raw Telemetry Ingestion via INCC TCP Socket

Monitoring Service

The Forteza persistent socket listener receives the raw frame over TCP port 6051. It immediately stores the raw string to disk and sends back an instant protocol ACK handshake to satisfy receiver timing.

RAW FRAME RECEIVED: 11 1001 18 E110 00 C001 INSTANT ACK SENT: 00 OKAY @
TokenParsed ValueDescription
R / L1 / 1Receiver #1, Line Card #1
ACCT1001Subscriber Account CSID
Format18Ademco Contact ID Standard
QEEvent Qualifier: 'E' = New Active Alarm ('R' = Restoral)
EEE110Standard Alarm Code: Fire Alarm
GG00Partition / Area 0
NNN001Zone Number 001
3

Entity Crosswalk: Mapping INCC Data to Property Master

Property Service Crosswalk

The raw numbers 1001 and 001 mean nothing to a human operator. The Crosswalk Engine queries the Shared Property Database to enrich this into a rich visual entity.

Raw Hardware KeyMapped Property EntityEnriched Information Available to Operator
ACCT: 1001Building ID: bld_shirke_5Shirke Mhada Building No. 5, Sector 4, Dharavi
ZONE: 001Zone ID: zone_fl3_serverFloor 3, Main Server Room, Optical Smoke #01
CODE: 110Alarm Condition: FIRE_ALARMPriority 1 (Critical Life Safety), Red Flashing Color
TOWN: MH_DHATown Authority: Dharavi Police / FireDirect Dispatch Phone: 022-24072222, Station 4
4

Real-Time WebSocket Push to Live CAD Alarm Board

React UI Dispatcher Screen

The normalized alarm is written to the Redis Live Queue and instantly pushed over WebSockets to all logged-in central station operators. The screen flashes red and sounds an urgent audible alert tone.

🚨
Operator Claim Locking
When Operator "David" clicks [CLAIM ALARM], a Redis distributed lock is placed. Other operators see a lock icon showing "Handled by David", preventing two dispatchers from calling the fire department at the same time!
5

Interactive Action Plan & Emergency Verification

Dispatcher Guidance SOP

The screen loads the pre-configured Action Plan (VERIFY_FIRST_THEN_DISPATCH). The operator does not have to remember what to do; the system guides them step-by-step:

Step A: Call Premise: Click-to-dial Building Security Desk (+91 98200 12345). Operator asks for verbal password ("Falcon").

Step B: Disposition Result: Operator clicks one of the buttons:

[DISP_REQ: Real Fire Confirmed] [NO_ANS: No Answer / Busy] [PASS_OK: Accidental Burn Toast / Password Verified]
6

Emergency Services Dispatch & Keyholder Broadcast

Notification Service

If no answer or real fire is confirmed, the system surfaces the direct Fire Brigade dispatch script with exact cross streets. Simultaneously, the system triggers automated SMS alerts to all property keyholders.

SCRIPT FOR OPERATOR: "This is Forteza Central Station ID #42 reporting a verified fire alarm at Shirke Mhada Building No. 5, Sector 4, Dharavi. Nearest cross street is 90 Feet Road. Smoke detected in 3rd Floor Server Room."
7

Incident Closure & Immutable Legal Audit Trail

Audit Trail & Regulatory Record

The operator selects the final resolution code (e.g. VALID_FIRE_DISPATCH), enters closing remarks, and closes the incident. Every millisecond, phone ring, and keystroke is saved into the permanent legal audit trail.

7

Step-by-Step Flow: SaaS Audit & Compliance Lifecycle

From Checklist Planning to On-Site Inspection and Official Certification

This is the commercial lifecycle used by external paying customers. It takes a building from initial registration through digital inspection, photo verification, defect resolution, and compliance certification.

1

Customer Registration & Property Onboarding

Subscriber & Property Service

Customer subscribes to a SaaS plan. They add their building into the Shared Property Registry: entering building height, floors, occupancy type (Commercial/Residential), and emergency contacts.

2

Audit Template Selection & Plan Creation

Audit Service

The facility manager chooses an official compliance template (e.g. "Annual High-Rise Fire Safety Audit - NBC Standard") and schedules the inspection date, assigning it to a certified auditor.

PropertyExample ValueDescription
template_idtpl_nbc_highrise_v2National Building Code standard questionnaire
building_idbld_shirke_5References the Shared Property Record
assigned_auditorAr. Sameer DesaiLicensed Fire Safety Engineer
planned_date2026-11-15Scheduled inspection execution date
3

On-Site Field Audit Execution (Mobile / Web)

Auditor Field Workspace

The auditor arrives on site with a tablet or mobile phone. They walk each floor, verifying safety items: fire pump pressure, emergency exit signage illumination, sprinkler shut-off valves, and extinguisher dates.

4

Defect Logging with Geotagged Photo Evidence

Defect Management

If an item fails (e.g. "Staircase A fire exit door blocked by cardboard boxes"), the auditor marks FAIL, takes an in-app photo, draws a red arrow over the blockage, and records a critical deficiency.

Deficiency FieldValueMeaning
severityCRITICALImmediate life-safety egress violation
photo_urls3://forteza-evidence/bld_1/staircase_a.jpgTimestamped image proof
corrective_actionRemove obstruction within 24 hoursPrescribed action for property manager
5

Corrective Action Workflow (CAPA)

Task Resolution

The building manager receives an instant SMS/Email notification. Their maintenance team removes the boxes, uploads a "Rectification Photo", and requests auditor sign-off.

6

Automated Scoring & Certificate Issuance

Certification Generator

Once verified, the engine computes the overall building score (e.g. 96%). The system stamps digital signatures and produces an official PDF Fire Safety Compliance Certificate with a verification QR code.

8

Complete Dataset Design & Relational Schema (ERD)

Bridging MicroKey Relational Architecture with the Shared Property Core

This entity model reconciles the MicroKey Alarm Monitoring Database (from your uploaded architecture specification and diagram) with the Forteza Property Core and the Audit Service:

properties_master Shared Core
PK property_idUUID
FK organization_idUUID
building_nameVARCHAR(100)
municipal_reg_noVARCHAR(50)
address_streetVARCHAR(150)
latitude, longitudeDECIMAL(10,7)
height_val, floorsINT
occupancy_typeVARCHAR(40)
FK town_code_idVARCHAR(20)
subscriber_panels (CSID) Monitoring
PK csidVARCHAR(20)
FK property_idUUID
receiver_lineVARCHAR(10)
port_numberINT
format_idVARCHAR(20)
hardware_modelVARCHAR(60)
is_on_test_modeBOOLEAN
verbal_passwordVARCHAR(50)
panel_zones Monitoring
PK zone_idBIGINT
FK csidVARCHAR(20)
zone_numberVARCHAR(10)
floor_areaVARCHAR(60)
sensor_descriptionVARCHAR(100)
FK condition_codeVARCHAR(20)
FK action_plan_idVARCHAR(30)
property_contacts Shared Core
PK contact_idBIGINT
FK property_idUUID
contact_name, titleVARCHAR(70)
phone_primaryVARCHAR(25)
phone_alt, emailVARCHAR(100)
call_priority_orderINT (1,2,3)
has_keysBOOLEAN
action_plans Monitoring
PK action_plan_idVARCHAR(30)
plan_descriptionVARCHAR(100)
require_verificationBOOLEAN
dispatch_agencyENUM('Police','Fire')
auto_dial_contactsBOOLEAN
escalation_timeout_secINT
audit_templates Audit Service
PK template_idUUID
titleVARCHAR(100)
compliance_codeVARCHAR(50)
passing_thresholdINT (e.g. 80%)
categories_schemaJSONB
questions_countINT
running_audits Audit Service
PK audit_idUUID
FK property_idUUID
FK template_idUUID
FK auditor_user_idUUID
statusENUM('Draft','Open','Closed')
final_scoreDECIMAL(5,2)
certificate_urlVARCHAR(255)
audit_findings Audit Service
PK finding_idUUID
FK audit_idUUID
item_code, titleVARCHAR(100)
statusENUM('Pass','Fail','NA')
severityENUM('Critical','Major')
photo_urlVARCHAR(255)
rectified_statusBOOLEAN
9

Single React Web Application & Role-Based Access Control (RBAC)

One Modern Codebase Dynamically Adapting to Every User Type

Instead of maintaining two completely separate frontends, we use the single React repository (D:\Office Project\Forteza\Frontend orteza-audit-system-frontend) and enforce dynamic navigation and permission gates based on user roles:

Role Target Persona Navigation Sidebar Items Visible Capabilities & Actions
SUPER_ADMIN Forteza Leadership / CTO Everything (CAD Monitor + SaaS Audit + Billing + Microservice Health) Full global access, configure system catalogs, manage tenants, override rules.
DISPATCHER Forteza Central Station Operator Live CAD Board, Real-Time Alarm Queue, Active Incidents, Test Modes Claim incoming alarms, execute SOP action plans, call emergency services, resolve events.
SAAS_TENANT_ADMIN External Customer / Building Owner My Buildings, Audit History, Compliance Scorecards, Team, Plan & Billing Register own buildings, schedule internal audits, download certificates, manage subscription.
FIELD_AUDITOR Safety Inspector / Engineer Assigned Audits, Field Inspection Checklist, Evidence Camera, Drafts Perform on-site inspections, mark pass/fail, take deficiency photos, submit reports.
TECHNICIAN Field Maintenance Contractor My Work Orders, Assigned Deficiencies, Rectification Proof Upload Review defects found during audit, upload repair photos, request re-inspection.
⚑
Frontend Implementation in React
In React Router, routes are wrapped with an <AuthGuard requiredRole={...}>. If a SaaS customer navigates to /monitoring/live-queue, the system displays a 403 Forbidden screen. The CAD Dispatcher screen enables full-screen mode, high-contrast dark theme, and sound effects, while the SaaS audit screen renders the clean Material-UI administrative dashboard.